D.E AG KNX Fancoil Actuator ANALOG 0-10V or PWM

DATEC
1630.02120/55100
New

It is device, for Heating or Cooling applications in offices, hotel rooms and much more.The fancoil can be used in Analog 0-10VDC or PWM mode. The fancoil actuator is able to drive up to three fan speeds and an additional 230VAC relay output.The device has two physical inputs, the first for connecting a local temperature sensor and the second to be used as binary input or as window contact input. 

check In Stock
Hurry! only 20 items left in stock.
€126.23
€148.50
Save 15%
Tax excluded
Quantity

Functional description

 FANCOIL ACTUATOR Heating or Cooling

 230VAC Power input is protected by a 5A T replaceable fuse

 Single output for heating or cooling valve

 Valve output can be set to analog 0-10VDC or 24VAC PWM (PWM Period can be set to several values between 15 seconds and 1 hour)

 FAN Output with 1, 2 or 3 fan speeds (separate 230VAC relay)

 Supplementary 230VAC Relay Output, for electric coil heating, cooling or other application

 Overload LED indicator with internal protection  Handmode is available for testing purpose, in order to check installation even without device being programmed or connected to KNX bus (Buttons to Increment / Decrement valve output, Increment fan speed, manually switch output Relay)

 Local temperature sensor input

 Local temperature sensor correction (A fixed value can be added or substracted to the measured temperature)

 Binary input or local window contact input, 24VDC with output limited to about 6mA provided by device. Needs only dry contact

 Operating LED for running or Handmode state indication

 To be mounted on 35mm DIN Rail  Operating temperature -5°C … +45°C  Housing 106mm (6 units) x 110 x 60mm 

: 1630.02120/55100
Hurry! only 20 items left in stock.
New

Use collapsible tabs for more detailed information that will help customers make a purchasing decision.

Ex: Shipping and return policies, size guides, and other common questions.

  • Paste the label on a flat surface on the package
  • Make sure that both 1D and 2D barcodes are clearly visible
  • Ensure that the label is smooth and isn’t creased or wrinkled
  • Check for any tears, dents, holes or scratches
  • Pack your product tightly, with the right size packaging
  • Ensure both barcodes are on a flat surface of the package
Size S M L XL
Men 7-10 10-13 13-15 15-17
Women 7-9 10-12 13-14 15-16

Example Shown : SIZE XL, Hem to Hem 84cm OR 33 ,SIZE L, Hem to Hem 84cm OR 33 ,SIZE M, Hem to Hem 84cm OR 33 ,SIZE S, Hem to Hem 84cm OR 33

You might also like