Input
Nominal Input Voltage | 100-240Vac |
Input Voltage Range | 90-277Vac |
Nominal Input Frequency | 50-60Hz |
Input Frequency Range | 47-63Hz |
Input Current | 1.80A typ. @ 115Vac, |
0.60A typ. @ 230Vac, | |
0.70A typ. @ 277Vac | |
Efficiency at 100% load | 89.0% typ. @ 115Vac, 91.5% typ. @ 230Vac & 277Vac |
Max. Inrush Current | 65A typ. @ 230Vac |
Power Factor | 0.98 typ. @ 115Vac, |
0.95 typ. @ 230Vac, | |
0.92 typ. @ 277Vac | |
Leakage Current | < 0.75mA @ 277Vac |
Output
Nominal Output Voltage | 12V |
Output Voltage Adjustment Range | |
Output Current Adjustment Range | |
Nominal Output Current | 13A |
Output Power | 156W |
Line Regulation | ± 0.5% (@ 100-277Vac input) |
Load Regulation | ± 2.0% (@ 100-277Vac input, 0-100% load) |
PARD | < 150mVpp |
Start-up Time | 1000ms typ. @ 115Vac (100% load) |
500ms typ. @ 230Vac & 277Vac (100% load) | |
Holdup Time | 16ms typ. @ 115Vac & 230Vac & 277Vac (100% load) |
Dynamic Response | ± 5% @ 0-100% load (Slew Rate: 0.1A/µS) |
Mechanical
Case Chassis / Case Cover | Aluminium |
Dimensions | 228 x 68 x 38.8 mm |
8.98" x 2.68" x 1.53" | |
Unit Weight | 1.04 Kg |
Cooling System | Convection |
Noise Sound Pressure Level (SPL) | Sound Pressure Level (SPL) < 25dbA |
Environment
Operating Ambient Temperature | -40°C to +70°C |
Storage Ambient Temperature | -40°C to +85°C |
Power De-rating | > 60°C de-rate power by 4% / °C |
< 100Vac de-rate power by 2% / Vac | |
Operating Humidity | 5 to 95% RH (Non-Condensing) |
Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions |
Vibration Test (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); |
20 min per axis for all X, Y, Z direction |