MULLER-CO2 -Sensore/Controllo Qualità Aria Regolazione Automatica/Manuale Temperatura

Mueller
GS 41.10
Nuovo
  • Rilevazione della qualità dell'aria (CO2, umidità relativa, temperatura)
  • Sensore di CO2 (campo di misura 390-10.000 ppm)
  • Sensori per la misura di CO2, temperatura, umidità e pressione atmosferica
  • Sensore di umidità (campo di misura 0 ..100% umidità relativa)
  • Sensore di temperatura (campo di misura 0°/50° C)
  • 5 ingressi binari e analogici
  • Regolazione manuale della temperatura di setpoint



block Esaurito
Esaurito
275,00 €
Tasse escluse
5/7gg lavorativi
Quantità

Preordine

Technical data

Supply voltage via KNX bus voltage
Bus current < 10 mA
Bus system KNX
Sensors CO2
Temperature
Relative humidity
Atmospheric pressure
Dew point
Manual operation
(only GS 41.10 knx)
manual adjustment of set-point temperature
(adjustment range ± 3° C, increment 0,5°)
Measuring range CO2-concentration 390-10.000 ppm
Measuring range temperature 0°...+50° C
Measuring range
relative humidity
0...100%
Measuring range
atmospheric pressure
300-1.100 hPa
Permitted ambient temperature 0°...+50° C
Housing self-extinguishing thermoplastic
Housing color studio white (similar to RAL 9016)
Mounting Wall mounting
(preferrably combined with hollow-wall box)
Type of connection
(KNX)
PCB push-in terminal block
Type of protection IP 20 (DIN EN 60529)
Class of protection III when installed according to regulations
Type of connection
external inputs
Wire diameter max. 6 x 0,5 mm²
strip length 7 mm

Functions and data provided to KNX bus:

CO2 Value output
Control (step and PI control)
Relative humidity Value output
Control (step and PI control)
Temperature Value output
Control heating (2-point- and PI control)
Control cooling (2-point- and PI control)
Alarms
Dewpoint Value output
Alarms
Air pressure Value output
VAV control Value output (0...100%)
: GS 41.10
Esaurito
Nuovo

Use collapsible tabs for more detailed information that will help customers make a purchasing decision.

Ex: Shipping and return policies, size guides, and other common questions.

  • Paste the label on a flat surface on the package
  • Make sure that both 1D and 2D barcodes are clearly visible
  • Ensure that the label is smooth and isn’t creased or wrinkled
  • Check for any tears, dents, holes or scratches
  • Pack your product tightly, with the right size packaging
  • Ensure both barcodes are on a flat surface of the package
SizeSMLXL
Men 7-10 10-13 13-15 15-17
Women 7-9 10-12 13-14 15-16

Example Shown : SIZE XL, Hem to Hem 84cm OR 33 ,SIZE L, Hem to Hem 84cm OR 33 ,SIZE M, Hem to Hem 84cm OR 33 ,SIZE S, Hem to Hem 84cm OR 33

Recensioni

Scrivi la tua recensione

MULLER-CO2 -Sensore/Controllo Qualità Aria Regolazione Automatica/Manuale Temperatura

  • Rilevazione della qualità dell'aria (CO2, umidità relativa, temperatura)
  • Sensore di CO2 (campo di misura 390-10.000 ppm)
  • Sensori per la misura di CO2, temperatura, umidità e pressione atmosferica
  • Sensore di umidità (campo di misura 0 ..100% umidità relativa)
  • Sensore di temperatura (campo di misura 0°/50° C)
  • 5 ingressi binari e analogici
  • Regolazione manuale della temperatura di setpoint



Scrivi la tua recensione