- Capacitive touch sensor for up to 25mm material size
- Three sensor panels enable button, double-click and wiping-gesture (acustic feedback customizable)
- Sensor panels can be used as one big panel
- Up to six switching options (acustic feedback customizable)
- Plastic housing (210x140x11 mm) robust against splash water
- Reset time programmable by switching timer
- KNX-Bus power required only
Enertex
It is able to drive a 5 A per channel, 12-24 VDC LED strip – that is a sum of 480 Watt dimming power or 120 Watt for each channel for 24 V LEDs.In device additionally a 16 A switching actuator with two timers is integrated. Thus, the LED power supply is powered on by the actuator if needed or turned off to minimize standby losses of the LED power supply.
It is able to drive a 5 A per channel, 12-24 VDC LED strip – that is a sum of 480 Watt dimming power or 120 Watt for each channel for 24 V LEDs.In device additionally a 16 A switching actuator with two timers is integrated. Thus, the LED power supply is powered on by the actuator if needed or turned off to minimize standby losses of the LED power supply.
- Up to 48 telegrams/second routing performance
- Up to 35 telegrams/second tunnelling performance
- Up to five KNXnet/IP tunnel connections
- Integrated display
- 10/100 MBit Ethernet interface
- Power over Ethernet or ext. 16-24 AC or 20-30V DC
- Battery buffered RTC
- SNTP server
- Telnet server
-
- Up to 48 telegrams/second routing performance
- Up to 35 telegrams/second tunnelling performance
- Up to five KNXnet/IP tunnel connections
- Integrated display
- 10/100 MBit Ethernet interface
- Power over Ethernet or ext. 16-24 AC or 20-30V DC
- Battery buffered RTC
- SNTP server
- Telnet server
IT is a bidirectional meter for measurement of active and reactive energy or power, respectively. Further it features an analysis of power supply quality.Measurements can be performed in a 3-phase system or in three independent 1-phase system.(current, voltage, active power, reactive power, active energy, reactive energy, power factor, THD-U, THD-I harmonics, unbalanced load, zero system current)
voltage input: 230 V AC (50Hz)
output current: 960 mA
Integrated choke
LEDs for operation, bus reset and programming mode
Integrated bus-connection with voltage and current measurement
Data output on KNX bus via group object and visible on display
KNX objects for voltage, current and power measurements
KNX alarm functions
Housing temperature measurement
AUX with 600mA additional output