KNX

KNX building automation is the automation of functions relating to electrical and technological systems. The KNX building automation system guarantees the best performance of the system in terms of safety, comfort and energy efficiency. Moreover building automation reduces operating times by modulating the power actually absorbed by adopting control strategies. Through KNX allows for scheduling, occupancy, gain, zoning. Furthermore, integrating, remoting, metering allow to reach a high degree of energy efficiency. Futhermore the bilding automation system is used in residential, tertiary, commercial, artisanal and public utility applications.

Active filters

  • Categories: Accessories
  • Categories: Horizentis Technology
  • Categories: Output Devices
  • Categories: System Devices
WEINZIERL KNX ENOCEAN 636 SECURE GATEWAY

KNX EnOcean 636 Secure Gateway is a bidirectional gateway between EnOcean wireless devices and the KNX bus. With the KNX EnOcean 636, commands and measured values from wireless EnOcean sensors can be transmitted to the KNX bus. It allows both KNX actuators and EnOcean actuators to be controlled via the KNX bus. The KNX EnOcean 636 Secure Gateway supports encrypted radio communication with security-enabled EnOcean devices. In addition, the Secure Gateway provides control and logic functions and includes a wireless repeater. The KNX EnOcean 636 supports more than 100 profiles with its 32 radio channels. Enables easy and secure connection of various KNX devices and EnOcean sensors and actuators. Commissioning is as simple as usual: With all 32 channels, encryption can be activated individually. Subsequently EnOcean sensors and actuators, which support safety, can be taught in. The user gets more safety without loss of comfort.

€428.40
WEINZIERL KNX RF / ENO PUSH BUTTON 440 SECURE

The KNX RF / ENO Push Button 440 secure unites two wireless protocols in one device: EnOcean and KNX RF. Out of the box the push button operates in EnOcean mode. EnOcean Secure can be enabled via pressing a key combination. By configuration with the ETS® the push button switches to KNX RF mode with optional support of KNX Data Security. Via a factory reset the device can be switched back to EnOcean protocol.

€104.90
WEINZIERL IP LINEMASTER 762.1 KNX SECURE

The KNX IP LineMaster 762.1 secure combines the essential functions of a KNX bus line: KNX power supply with choke, KNX IP router and KNX IP interface. In addition to the bus voltage the power supply offers an auxiliary voltage.

The KNX IP router in the KNX IP LineMaster 762.1 secure allows forwarding of telegrams between different lines through a LAN (IP) as a fast backbone. Using the embedded KNX IP interface, the KNX line can be connected directly to a PC (e.g. by ETS). The device supports KNX Security which can be enabled in ETS. As secure router the device allows coupling of not secured communication on KNX TP to a secured IP backbone. Also for the interface functionality (unneling) KNX security prevents from unauthorized access. The IP address can be obtained by a DHCP server or by manual configuration (ETS) respectively.

This device works according to the KNXnet/IP specification using the core, the device management, the tunneling and the routing part. The KNX IP LineMaster 762.1 secure has an extended filter table for main groupls 0 to 31 and is able to buffer up to 150 telegrams.

€551.70
WEINZIERL Blind Actuator KNX IO 520 (1J2I)

The Blind Actuator KNX IO 520 (1J2I) is a compact blind actuator with two additional binary inputs. The actuator is used to control a blind, a shutter or a window drive. The relay contacts are electrically interlocked. The inputs Blind Actuator KNX IO 520 (1J2I) can be connected to conventional switches with an external voltage of 12 to 230 V. In the not configured state the binary inputs control the actuator channel. Via commissioning the device using ETS® software the binary inputs can be used independently. Two push buttons and three LEDs allow a local operation and a visualization of the device state. In addition to the output and input channels the Blind Actuator KNX IO 520 (1J2I) includes 16 independent functions for logic or timer control.

  • ▪ 1 shutter output, 230 V∿, 8 A
  • ▪ Drive directions electro-mechanically locked against each other
  • ▪ For blinds, shutters or window drives
  • ▪ Approach position via time calculation
  • ▪ 2 inputs 12..230 V⎓∿, galvanically isolated
  • ▪ Switching, dimming, shutters, scenes, pulse counter
  • ▪ Integrated logic and timer functions
  • ▪ Connections: KNX, plugable screw terminals for IO
  • ▪ For DIN rail, width 1 unit (18 mm)
€106.30
WEINZIERL Universal dimming actuator KNX IO 530 (1D2I)

The Universal dimming actuator KNXIO 530 (1D2I) is a compact mains dimmer for 230 V ~ with one output and two binary inputs. The dimming actuator supports phase control or phase section and is thus suitable for all dimmable 230 V lamps (eg incandescent lamps, dimmable LED lamps, halogen lamps). The dimming channel offers various comfort functions, including scenes, automatic, snooze function, staircase lighting and sequencer.The inputs of Universal dimming actuator KNXIO 530 (1D2I) can be controlled via conventional switches with an external voltage of 230 V. In addition to the output and input channels, the Universal dimming actuator KNXIO 530 (1D2I) contains 16 independent logic or timer functions. Two buttons and three LEDs on the front of the device allow local operation and visualization of the device status.

€138.90
DATEC Datec Electronic AG EIB/KNX Motor Control...

It is a flush mounted device,for ceiling fan applications in offices, hotel rooms..It is used for varying ceiling fan speed as determined by KNX input or control systems.Also,speed can be varied by push buttons directly connected to the MOTOR CONTROL device.The ceiling fan must be of standard motor type, without control electronics. If using multiple speed fans, always force fan in max speed.

€130.90
Interra Line Coupler

Basic functionality of the TP line coupler ITR901-002 is coupling two KNX TP lines (main line and subline) providing galvanic isolation in between. Due to its flexibility ITR901-002 coupler unit can be used as KNX line coupler or KNX area coupler (to connect a TP line to a TP area or backbone) or KNX repeater (without filtering). Operational and filtering states, malfunction and faulty communication are indicated by LEDs. 

Download  DATASHEET

Download DATABASE ETS

€170.00
DINUY DINUY RF KNX 1-channel Switch actuator...
  • Wireless 1-channel Switch actuator for general purpose.
  • Up to 16A switching capacity with non-free voltage output.
    Two different operation modes:
    · Switch ON/OFF.
    · Timer: 3sec ~ 5min.
  • Incorporates RF signal repeater function, which can be enabled or disabled as needed.
  • A conventional pushbutton can be wired for local control.
  • DIN-rail mounting. Dimensions: 1 module wide.
  • 230V-operated.
  • Radio-frequency: 868,4MHz.
  • Range: up to 100m (in the free field).
  • Compatible with: EM KNX 002, PU KNX 001, RC KNX 001, SE KNX 003, DM KNX 001, DM KNX 002 & CO KNX 002.
€144.48
EAE EAE Technology PS320 Power Supply...

EAE KNX Power Supply - 320 mA version. Features an additional 30V DC output, NOT to power an additional KNX bus.

  • Input voltage range 150-275V AC, 50 60Hz
  • Output 1: KNX bus power with an integrated choke. (30VDC, SELV)
  • Output 2: Additional voltage output. (30VDC, SELV)
  • Short-circuit and overload protected outputs
  • LED indicators for Power, Overload and Reset status
  • On device reset with Reset Button

Download DATASHEET

Download MANUALE PRODOTTO

Download MANUALE INSTALLAZIONE

€175.00
EAE EAE Technology PS640 Power Supply...

EAE KNX Power Supply - 640 mA version. Features an additional 30V DC output, NOT to power an additional KNX bus.

  • Input voltage range 150-275V AC, 50 60Hz
  • Output 1: KNX bus power with an integrated choke. (30VDC, SELV)
  • Output 2: Additional voltage output. (30VDC, SELV)
  • Short-circuit and overload protected outputs
  • LED indicators for Power, Overload and Reset status
  • On device reset with Reset Button

Download DATASHEET

Download MANUALE PRODOTTO

Download MANUALE INSTALLAZIONE

€210.00
EAE EAE Technology IPR100 IP Router KNXnet/IP...

EAE KNX IP router is used as a line or backbone coupler to ensure communication between KNXnet/IP and TP KNX bus line. Electrical insulation is also achieved between the linked lines.

  • EAE KNX IP router is a tunneling and routing device. IPR100 is used as a gateway between IP and KNX bus line for commissioning and monitoring purposes. (It is also possible to simultaneously create 4 KNXnet/IP connections).
  • Simultaneous connection to two different KNX systems and transmission of telegrams between the local network and different buses
  • IP address assignment manually or by DHCP server
  • Option to block or allow telegrams between KNX and IP regarding configured filter table
  • Deactivation of filter table using on-device buttons for quick diagnosis
  • Functional status information with 6 LEDs on device

Download DATASHEET

Download MANUALE PRODOTTO

Download DATABAESE ETS

€485.00
EAE EAE Technology Switch Actuator 8x16A 500A...

In addition to switching resistive loads, SA108 is designed to be used with capacitive and inductive loads, enabling a convenient control of fluorescent ballasts and led drivers.

8 independently configurable channels

Manual control for each relay on the device using slide switches

Does not require an external power supply

Electric current control can be configured

Following functions can be defined separately for each channel:

  • Stair function
  • External logic
  • Internal logic
  • Priority function
  • Threshold function
  • Transaction time
  • Sweep function

Download   DATASHEET

Download   MANUALE 

Download   DATABASE ETS

€265.00
EAE EAE Technology Switch Actuator 4x16A 500A...

In addition to switching resistive loads, SA104 is designed to be used with capacitive and inductive loads, enabling a convenient control of fluorescent ballasts and led drivers.

4 independently configurable channels

Manual control for each relay on the device using slide switches

Does not require an external power supply

Electric current control can be configured

Following functions can be defined separately for each channel:

  • Stair function
  • External logic
  • Internal logic
  • Priority function
  • Threshold function
  • Transaction time
  • Sweep function

Download   DATASHEET

Download   MANUALE 

Download   DATABASE ETS

€185.00
WAGO 221-412 Flexible wire clamp: 0.14-4...

 

Pack Quantity 100 pz.
Type 221
Article Part No. 221-412
Flexible section (max.) 4 mm²
Category Clamp
Connection Spring
Color Trasparent, Orange
Insulation material Plastic
Rigid cross-section (min.) 0.2 mm²
Length - Depth 18.6 mm
Nom. Voltage 450 V
Stripping length 11 mm
Compatibile RoHS
Flexible section (min.) 0.14 mm²
Pol2 2
AWG 24 - 12
Width 13.1 mm
Current 32 A
Temperature range fino a +105 °C
Rigid cross-section  (max.) 4 mm²
€19.26
Enertex® E.B® KNX 4Channel LED DimSequencer 5A DK...

It is able to drive a 5 A per channel, 12-24 VDC LED strip – that is a sum of 480 Watt dimming power or 120 Watt for each channel for 24 V LEDs.In device additionally a 16 A switching actuator with two timers is integrated. Thus, the LED power supply is powered on by the actuator if needed or turned off to minimize standby losses of the LED power supply. 

€222.50
Enertex® E.B® KNX 4Channel LED DimSequencer 5A REG...

It is able to drive a 5 A per channel, 12-24 VDC LED strip – that is a sum of 480 Watt dimming power or 120 Watt for each channel for 24 V LEDs.In device additionally a 16 A switching actuator with two timers is integrated. Thus, the LED power supply is powered on by the actuator if needed or turned off to minimize standby losses of the LED power supply. 

€207.50
Enertex® Enertex® KNX PowerSupply 960mA & Voltage...

voltage input: 230 V AC (50Hz)

output current: 960 mA

Integrated choke

LEDs for operation, bus reset and programming mode

Integrated bus-connection with voltage and current measurement

Data output on KNX bus via group object and visible on display

KNX objects for voltage, current and power measurements

KNX alarm functions

Housing temperature measurement

AUX with 600mA additional output

€250.50