Active filters
EAE KNX Power Supply - 320 mA version. Features an additional 30V DC output, NOT to power an additional KNX bus.
- Input voltage range 150-275V AC, 50 60Hz
- Output 1: KNX bus power with an integrated choke. (30VDC, SELV)
- Output 2: Additional voltage output. (30VDC, SELV)
- Short-circuit and overload protected outputs
- LED indicators for Power, Overload and Reset status
- On device reset with Reset Button
Download DATASHEET
Download MANUALE PRODOTTO
Download MANUALE INSTALLAZIONE
EAE KNX Power Supply - 640 mA version. Features an additional 30V DC output, NOT to power an additional KNX bus.
- Input voltage range 150-275V AC, 50 60Hz
- Output 1: KNX bus power with an integrated choke. (30VDC, SELV)
- Output 2: Additional voltage output. (30VDC, SELV)
- Short-circuit and overload protected outputs
- LED indicators for Power, Overload and Reset status
- On device reset with Reset Button
Download DATASHEET
Download MANUALE PRODOTTO
Download MANUALE INSTALLAZIONE
EAE KNX IP router is used as a line or backbone coupler to ensure communication between KNXnet/IP and TP KNX bus line. Electrical insulation is also achieved between the linked lines.
- EAE KNX IP router is a tunneling and routing device. IPR100 is used as a gateway between IP and KNX bus line for commissioning and monitoring purposes. (It is also possible to simultaneously create 4 KNXnet/IP connections).
- Simultaneous connection to two different KNX systems and transmission of telegrams between the local network and different buses
- IP address assignment manually or by DHCP server
- Option to block or allow telegrams between KNX and IP regarding configured filter table
- Deactivation of filter table using on-device buttons for quick diagnosis
- Functional status information with 6 LEDs on device
Download DATASHEET
Download MANUALE PRODOTTO
Download DATABAESE ETS
- Communication with 8 IP cameras with 8 input and 8 output objects each
- Transfer of the camera events to the KNX bus
- Controlling the camera via the KNX bus
- KNX Bus Terminal and Ethernet / IP Connection (POE)
- Suitable for IP cameras that meet the communication requirements as described in the camera settings in the manual
- Configuration via ETS 5
- Up to 48 telegrams/second routing performance
- Up to 35 telegrams/second tunnelling performance
- Up to five KNXnet/IP tunnel connections
- Integrated display
- 10/100 MBit Ethernet interface
- Power over Ethernet or ext. 16-24 AC or 20-30V DC
- Battery buffered RTC
- SNTP server
- Telnet server
-
- Up to 48 telegrams/second routing performance
- Up to 35 telegrams/second tunnelling performance
- Up to five KNXnet/IP tunnel connections
- Integrated display
- 10/100 MBit Ethernet interface
- Power over Ethernet or ext. 16-24 AC or 20-30V DC
- Battery buffered RTC
- SNTP server
- Telnet server
voltage input: 230 V AC (50Hz)
output current: 960 mA
Integrated choke
LEDs for operation, bus reset and programming mode
Integrated bus-connection with voltage and current measurement
Data output on KNX bus via group object and visible on display
KNX objects for voltage, current and power measurements
KNX alarm functions
Housing temperature measurement
AUX with 600mA additional output
The KNX POWER SUPPLY 640mA is a DIN Rail mounted KNX device with integrated choke, to directly power a KNX line. An auxiliary 30V output is available for some extra loads, as displays, binary inputs, …
The KNX USB interface ITR901-003 provides a galvanic isolated bidirectional connection to the bus system via KNX TP and USB. Network configurations become less time-consuming. The device is supplied by both the KNX TP line and USB. No additional external power supply is necessary.
Download DATASHEET