Digital time switches 4 channels

0 Review(s) 
SC 98.40
New product
  • Daily, weekly and yearly program
  • 10 years battery-reserve
  • Up to 300 permanent switchings by date
  • Manual permanent mode
  • Automatic sorting of switching times on readout
  • Fully automatic daylight saving time
  • Elapsed time and pulse counter
  • Pulse function
  • Cycle function
  • Timer function
  • Channel button function
  • DCF function
  • Security by PIN-Code
  • Illuminated display
  • Data-key function
€259.00
Tax excluded

ZD4i%20Multisensore%20Zhaga%20Light%20Controller%20Ouydoor%202.jpg

Technical data

Supply voltage via KNX-Bus voltage
Bus current max. 25 mA
Bus system KNX
Switching functions ON
OFF
pulse
cycle
yearly program
Pulse length Pulse function
(switching time)
00:01 up to 59:59 mm:ss
Pulse length Timer
(man. switching)
0:00:01 up to 9:59:59 h:mm:ss
Pulse/Pause length
Cycle
0:00:01 up to 9:59:59 h:mm:ss
Memory locations 300
Minimum interval 1 min.
Time base Quartz
KNX-Bus
DCF / GPS (optional accessory)
Quartz accuracy
(at 20°C)
≤ ±0,25 Sec./day
(Quartz accuracy optimized for typical ambient conditions)
Power back-up
(at 20°C)
approx. 10 years
(depends on the Lithium-battery life)
Program security unlimited (E2-PROM)
Display high resolution LCD
(visible area 12,8 cm2)
Permitted ambient temperature -30°...+55°C
Housing self-extinguishing thermoplastic
Dimensions 45 x 71,5 x 58 mm
Mounting 35 mm DIN-rail
Type of connection KNX-Bus-terminal
Screw terminals (for radio receiver)
Type of protection IP 20 to DIN EN 60529
Class of protection II when installed according to regulations
Accessories
(not included in delivery)
Data-key DK pro
Programming package PP50 pro / PP60 pro
Radio receiver DCF-time FU 20.00 pro
Radio receiver GPS-time FU 3x.00 pro
Radio receiver GPS for KNX FU 40.00 knx

Following data and functions will be offered for the KNX bus:

Switching [1 bit] Time dependent switching
Priority [2 bit] Priority / control based switching
Value [1 byte] Transmits a 1 byte integer number
Value [2 byte] Transmits a 2 byte integer number
Float [2 byte] Transmits a 2 byte floating point number
Float [4 byte] Transmits a 4 byte floating point number
Scene control [1 byte] Up to 64 scenes
HVAC
[1 byte]
Heating
ventilating
air conditioning
4x Logic Gates With and / or / xor / and with feedback. Each with up to 4 logic inputs selectable between internal (time switch, output of other logic gates) and external 1 bit values (from the bus). Output can be selected between 1 bit and 1 byte values.
SC 98.40
New product

Reviews

Write your review

Digital time switches 4 channels

  • Daily, weekly and yearly program
  • 10 years battery-reserve
  • Up to 300 permanent switchings by date
  • Manual permanent mode
  • Automatic sorting of switching times on readout
  • Fully automatic daylight saving time
  • Elapsed time and pulse counter
  • Pulse function
  • Cycle function
  • Timer function
  • Channel button function
  • DCF function
  • Security by PIN-Code
  • Illuminated display
  • Data-key function

Write your review